Features
Input for Strain Gauge
Input range configurable from 0÷10 mV up to 0÷200 mV or from ± 5 mV up to ± 200 mV
Accurate bridge excitation voltage at 3.6 and 10 Vdc with current limiter
Isolated power supply source for passive loads on output
Input and output ranges configurable by DIP-switches
Galvanic isolation at 2000 Vac between input, power supply and output
Good accuracy and performance stability
EMC compliant – CE mark
DIN rail mounting in compliance with EN-50022 and EN-50035
General Description
The converter DAT 5025 is designed to provide on its output a voltage or current signal linear and proportional with the output voltage coming from the output of a bridge transducers applied on its input.
The user can program the bridge excitation voltage value, the input and the output ranges by the proper DIP-switches available after opening the suitable door located on the side of device (see “Input ranges table” and “Output ranges table” sections).
The regulation of Zero and Span values is made by the ZERO and SPAN potentiometers located on the top of device.
The 2000 Vac isolation between input, power supply and output eliminates the effects of all ground loops eventually existing and allows the use of the converter in heavy environmental conditions found in industrial applications.
The DAT 5025 provides on the output side an auxiliary supply source to connect both active and passive loads.
It is housed in a plastic enclosure of 12.5 mm thickness suitable for DIN rail mounting in according to EN-50022 and EN-50035 standards .